Technical data for the EXACTUS® HELIOS. Items marked TBD are pending confirmation and should not be treated as final.
| Range | 400–2000 °C / 752–3632 °F |
|---|---|
| Modes | Instant, Average, Minimum, Maximum |
| Accuracy | ± 1.5 °C or 0.2 % of measured temperature |
| Drift | 0.10 °C per year max |
| Emissivity adjustment | 0.01 – 1.20 (default 1.00) |
| Optics | Fixed focus |
| Target / spot size | 20 mm at 1–2 m, 30 mm at 3 m |
| Spectral response | 1 µm |
| Camera | 2 MP global shutter |
| Laser | Class II, < 1 mW |
| Storage | 16 GB — approximately 300,000 measurements |
| Power source | Li-ion 2-cell (1S2P) 3.7 V, 5200 mAh, 19.2 Wh — user-replaceable |
| Weight | 600 g (1.3 lb) |
| Operating range | 10–60 °C |
| Sealing | IP61 |
| Display | 4-inch touchscreen |
Approvals
The EXACTUS® HELIOS (H01) has been tested to and found in compliance with the harmonized standards under the EU Low Voltage Directive (2014/35/EU) and the EU Electromagnetic Compatibility Directive (2014/30/EU), supporting the CE mark.
Safety — LVD 2014/35/EU
Tested to the harmonized safety standard for the EU Low Voltage Directive:
Test report HS-2025001-L1, issued 1 Dec 2025.
Testing body: EU Certification Technology Co., Ltd. (Taichung City, Taiwan).
EMC — EMC Directive 2014/30/EU
All emission and immunity tests returned a PASS result against the harmonized standards:
Coverage: conducted & radiated emissions (< 1 GHz), ESD, RF field immunity, and power-frequency magnetic-field immunity — all within limits.
Test report EC5N0403 (Version 01), issued 8 Dec 2025.
Testing laboratory: Sporton International Inc., Hsinhua Laboratory (Taoyuan City, Taiwan).
Identification
The Helios carries a nameplate label with the serial number, hardware version, and order code. Quote the serial number and firmware version (from About This Device) when contacting support.
Label fields